Adding a Valve
In Desigo CC, there are default valves for all geographic directions, 2 or 3-port valves, and technical versions. After adding the graphic, the default valve is configured as per project requirements.
- In the Mode group, conduct one of the following actions:
 
- Click Design 
. Previously rotated objects appear in the default direction. 
- (Optional) Click Test 
. In this case, the valve does not display in its true size. 
- In System Browser, select logical view.
 
- Select Logical > [Network name] \...\ [Plant] >
 
- [PreHcl (preheater)] > [Vlv (valve)]
 
- [ReHcl (reheater)] > [Vlv (valve)]
 
- [Ccl (cooling coils)] > [Vlv (valve)]
 
- [Hum (humidifier)] > [Vlv (valve)]
 
- Drag the object to the graphics page.
 
- The added object displays at the maximum scale. This ensures that the next object does not overlap. 

 
Rotating
- The fan symbol is added to the graphic.
 
- In the Mode group, click Test
. 
- The valve symbol displays as per default direction 
. 
- Select the valve symbol.
 
- Left-click and hold, then right-click until the valve symbol displays in the desired direction.
 
- Release the left mouse button.
 
- The valve symbol 
 is displayed in the desired direction. 
Valve Direction  | ||||
Direct Entry of Direction under Symbol Properties > Substitution > Direction  | ||||
0  | 1  | 2  | 3  | 4  | 
  | 
  | 
  | 
  | 
  | 

NOTE:
In drawing mode, the fan is always displayed in the default state.
Changing a 2 / 3-Port and Actuator Type
- The fan symbol is added to the graphic.
 
- In the View tab, select Properties.
 
- The Symbol Properties dialog box is enabled.
 
- In the Mode group, click Test
. 
- The valve symbol displays as per the valve type and the selected direction 
. 
- Select the valve symbol.
 
- Select Symbol Properties > Substitutions.
 
- In the 2 or 3 Port field, enter a number:
 
- 2 for 2-port valve 
. 
- 3 for 3-port valve 
. 
- In the Type field, enter a number from 0 through 2 (see Table Valve Types).
 
- Click ENTER or change to another entry field to activate the change.
 
- (Optional) Change valve symbol.
a. Right-click the symbol and select Symbol Instance > Replace. An object reference must be assigned to change the symbol.
b. Select the new valve symbol. 
Valve Types  | ||||||
Type  | Analog  | Digital  | ||||
0 Neutral  | 
  | 
  | 
  | 
  | 
  | 
  | 
1 Motor  | 
  | 
  | 
  | 
  | 
  | 
  | 
2 Magnet  | 
  | 
  | 
  | 
  | 
  | 
  | 

NOTE:
In drawing mode, the fan is always displayed in the default state (neutral).